Analog photoelectric smoke detectors

Corodex

Analog photoelectric smoke detectors

FDKU012-PSA
  • Low profile, less than 2 inches with the base
  • Wide sensitivity range of 3.4 to 12.0%/m (1.05 to 3.82%/foot)
  • True analog detector
  • UL listed smoke calibration and sensitivity
  • Simple and accurate address set t ing wi thout mechanical switches
  • LEDs for 360° viewing
  • 22.0 to 24.0V for working voltage range of SLC
  • UL listed
Corodex
FDKU026-D-X
  • Very low profile (28.7mm/1.13-inch only in height)
  • Wide alarm set-point range of 3.4 to 11.6%/m (1.05 to 3.69%/foot)
  • True analog detector
  • UL listed smoke calibration and sensitivity
  • Simple and accurate address set t ing wi thout mechanical switches
  • LEDs for 360° viewing
  • 22.0 to 24.0V for working voltage range of SLC
  • UL listed
Corodex

Analog fixed temperature heat detectors

FDLU009-FHA
  • 57°C to 85°C (135°F to 185°F) heat sensor
  • Low profile
  • Simple and accurate address set t ing wi thout mechanical switches
  • LEDs for 360° viewing
  • Ambient temperature listing of 0°C to 66°C (32°F to 150°F)
  • 22.0 to 24.0V for working voltage range of SLC
  • UL listed
Corodex
FDLU019-D-X
  • Very low profile (30.7mm/1.21-inch only in height)
  • 57°C to 85°C (135°F to 185°F) heat sensor
  • True analog detector
  • Ambient temperature listing of 0°C to 66°C (32°F to 150°F)
  • Simple and accurate address set t ing wi thout mechanical switches
  • LEDs for 360° viewing
  • 22.0 to 24.0V for working voltage range of SLC
  • UL listed
Corodex

Analog rate-of-rise/fixed-temp. combination heat detectors

FDHU002-RHA
  • Adjustable fixed 57°C to 79°C (135°F to 174°F )
  • Rate-of-rise feature
  • Simple and accurate address set t ing wi thout mechanical switches
  • LEDs for 360° viewing
  • 22.0 to 24.0V for working voltage range of SLC
  • UL listed
Corodex
FDHU003-D-X
  • Very low profile (30.7mm/1.21-inch only in height)
  • Adjustable fixed 57°C to 79°C (135°F to 174°F)
  • True analog detector for fixed temperature
  • Rate-of-rise feature
  • Simple and accurate address setting without mechanical switches
  • LEDs for 360° viewing
  • 22.0 to 24.0V for working voltage range of SLC
  • UL listed
Corodex

Analog photoelectric-smoke/fixed-temp-heat combination detectors

FDKLU001-PSHA
  • Wide sensitivity range of 3.4 to 12.0%/m (1.05 to 3.82%/foot)
  • 57°C (135°F) restorable heat detector
  • True analog detector
  • Simple and accurate address setting without mechanical switches
  • LEDs for 360° viewing
  • 22.0 to 24.0V for working voltage range of SLC
  • UL listed
Corodex
FDKLU026-D-X
  • Very low profile (38.0mm/1.50-inch only in height)
  • Wide alarm set-point range of 3.4 to 11.6%/m (1.05 to 3.69%/foot)
  • 57°C (135°F) restorable heat detector
  • True analog detector
  • Simple and accurate address setting without mechanical switches
  • LEDs for 360° viewing
  • 22.0 to 24.0V for working voltage range of SLC
  • UL listed
Corodex

Analog photoelectric projected beam smoke detector, FDGJ002-D-X

  • Wide and high coverage within 100m distance
  • Sensitivity drif t compensation for contamination or a slight shift in the optical system
  • Light synchronized system to prevent false alarms
  • Simple optical axis setting
  • Simple and accurate address setting without mechanical switches
  • 24VDC for rated operating voltage of SLC